Drivers SIS Hard Disk Controller



This page contains the driver installation download for SiS 5513 IDE UDMA Controller in supported models (AWRDACPI) that are running a supported operating system. If you have a PC you can simply re-install the hard drive as a slave when you have finished swapping the controller. I currently don't have a PC and wanted to be able to interface the hard drive to my laptop so I procured a USB 2.0 to IDE / SATA adapter from Amazon for about $20. The adapter ended up working fine, but the power adapter that it came with did not work, so I used an old PC power. By default, the virtual SCSI controller is assigned to virtual device node (z:7), so that device node is unavailable for hard disks or other devices. If you add a SATA controller, you can reassign an existing or new hard disk or device to that controller.

(Redirected from Run length limited)

Run-length limited or RLL coding is a line coding technique that is used to send arbitrary data over a communications channel with bandwidth limits. RLL codes are defined by four main parameters: m, n, d, k. The first two, m/n, refer to the rate of the code, while the remaining two specify the minimal d and maximal k number of zeroes between consecutive ones. This is used in both telecommunication and storage systems that move a medium past a fixed recording head.

Specifically, RLL bounds the length of stretches (runs) of repeated bits during which the signal does not change. If the runs are too long, clock recovery is difficult; if they are too short, the high frequencies might be attenuated by the communications channel. By modulating the data, RLL reduces the timing uncertainty in decoding the stored data, which would lead to the possible erroneous insertion or removal of bits when reading the data back. This mechanism ensures that the boundaries between bits can always be accurately found (preventing bit slip), while efficiently using the media to reliably store the maximal amount of data in a given space.

Early disk drives used very simple encoding schemes, such as RLL (0,1) FM code, followed by RLL (1,3) MFM code, which were widely used in hard disk drives until the mid-1980s and are still used in digital optical discs such as CD, DVD, MD, Hi-MD and Blu-ray. Higher-density RLL (2,7) and RLL (1,7) codes became the de facto industry standard for hard disks by the early 1990s.

Need for RLL coding[edit]

Sis Graphics Drivers

On a hard disk drive, information is represented by changes in the direction of the magnetic field on the disk, and on magnetic media, the playback output is proportional to the density of flux transition. In a computer, information is represented by the voltage on a wire. No voltage on the wire in relation to a defined ground level would be a binary zero, and a positive voltage on the wire in relation to ground represents a binary one. Magnetic media, on the other hand, always carries a magnetic flux – either a 'north' pole or a 'south' pole. In order to convert the magnetic fields to binary data, some encoding method must be used to translate between the two.

One of the simplest practical codes, modified non-return-to-zero-inverted (NRZI), simply encodes a 1 as a magnetic polarity transition, also known as a 'flux reversal', and a zero as no transition. With the disk spinning at a constant rate, each bit is given an equal time period, a 'data window', for the magnetic signal that represents that bit, and the flux reversal, if any, occurs at the start of this window. (Note: older hard disks used one fixed length of time as the data window over the whole disk, but modern disks are more complicated; for more on this, see zoned bit recording.)

This method is not quite that simple, as the playback output is proportional to the density of ones, a long run of zeros means no playback output at all.

In a simple example, consider the binary pattern 101 with a data window of 1 ns (one nanosecond, or one billionth of a second). This will be stored on the disk as a change, followed by no change, and then another change. If the preceding magnetic polarity was already positive, the resulting pattern might look like this: −−+. A value of 255, or all binary ones, would be written as −+−+−+−+ or +−+−+−+−. A zero byte would be written as ++++++++ or −−−−−−−−. A 512-byte sector of zeros would be written as 4096 sequential bits with the same polarity.

Since a disk drive is a physical piece of hardware, the rotational speed of the drive can change slightly, due to a change in the motor speed or thermal expansion of the disk platter. The physical media on a floppy disk can also become deformed, causing larger timing errors, and the timing circuit on the controller itself may have small variations in speed. The problem is that, with a long string of zeros, there's no way for the disk drive's controller to know the exact position of the read head, and thus no way to know exactly how many zeros there are. A speed variation of even 0.1%, which is more precise than any practical floppy drive, could result in 4 bits being added to or removed from the 4096-bit data stream. Without some form of synchronization and error correction, the data would become completely unusable.

Sis Drivers Download

The other problem is due to the limits of magnetic media itself: it is only possible to write so many polarity changes in a certain amount of space, so there's an upper limit to how many ones can also be written sequentially, this depends on the linear velocity and the head gap.

To prevent this problem, data is coded in such a way that long repetitions of a single binary value do not occur. By limiting the number of zeros written consecutively, this makes it possible for the drive controller to stay synchronized. By limiting the number of ones written in a row, the overall frequency of polarity changes is reduced, allowing the drive to store more data in the same amount of space, resulting in either a smaller package for the same amount of data or more storage in the same size package.

History[edit]

All codes used to record on magnetic disks have limited the length of transition-free runs and can therefore be characterized as RLL codes. The earliest and simplest variants were given specific names, such as modified frequency modulation (MFM), and the name 'RLL' is commonly used only for the more complex variants not given such specific names, but the term technically applies to them all.

The first 'RLL' code used in hard drives was RLL (2,7), developed by IBM engineers and first used commercially in 1979 on the IBM 3370 DASD,[1][2][3] for use with the 4300 series mainframe. During the late 1980s, PC hard disks began using RLL proper (i.e. variants more complex than those that had received their own proper names, such as MFM). RLL codes have found almost universal application in optical-disc recording practice since 1980. In consumer electronics, RLLs like the EFM code (rate = 8/17, d = 2, k = 10) are employed in the Compact Disc (CD) and MiniDisc (MD), and the EFMPlus code (rate = 8/16, d = 2, k = 10) used in the DVD. Parameters d and k are the minimal and maximal allowed run lengths. For more coverage on the storage technologies, the references cited in this article are useful.[4][5]

Technical overview[edit]

Generally run length is the number of bits for which signal remains unchanged. A run length of 3 for bit 1, represents a sequence 111. For instance, the pattern of magnetic polarizations on the disk might be +−−−−++−−−++++++, with runs of length 1, 4, 2, 3, and 6. However, run-length limited coding terminology assumes NRZI encoding, so 1 bits indicate changes and 0 bits indicate the absence of change, the above sequence would be expressed as 11000101001000001, and only runs of zero bits are counted.

Somewhat confusingly, the run length is the number of zeros (0, 3, 1, 2 and 5 in the preceding) between adjacent ones, which is one less than the number of bit times the signal actually remains unchanged. Run-length limited sequences are characterized by two parameters, d and k, which stipulate the minimal and maximal zero-bit run length that can occur in the sequence. So RLL codes are generally specified as (d,k) RLL, e.g.: (1,3) RLL.

Coding[edit]

In the encoded format a '1' bit indicates a flux transition, while a '0' indicates that the magnetic field on the disk does not change for that time interval.

FM: (0,1) RLL[edit]

Generally, the term 'RLL code' is used to refer to more elaborate encodings, but the original Frequency Modulation code, also called differential Manchester encoding, can be seen as a simple rate-1/2 RLL code.The added 1 bits are referred to as clock bits.

DataEncoded
010
111

Drivers Sis Hard Disk Controller Gamepad

Example:

GCR: (0,2) RLL[edit]

By extending the maximal run length to 2 adjacent 0 bits, the data rate can be improved to 4/5. This is the original IBM group coded recording variant.

DataEncoded
000011001
000111011
001010010
001110011
010011101
010110101
011010110
011110111
DataEncoded
100011010
100101001
101001010
101101011
110011110
110101101
111001110
111101111

Where possible (11 out of 16 codes), the bit pattern abcd is encoded by prefixing it with the complement of a: aabcd. In the 5 cases where this would violate one of the rules (000d or ab00), a code beginning with 11 is substituted (11bea, where e = ad).

Example:

Note that to meet the definition of (0,2) RLL, it is not sufficient only that each 5-bit code contain no more than two consecutive zeros, but it is also necessary that any pair of 5-bit codes as a combined sequentially not contain more than two consecutive zeros. That is, there must not be more than two zeros between the last one bit in the first code and the first one bit in the second code, for any two arbitrarily chosen codes. This is required because for any RLL code, the run-length limits – 0 and 2 in this case – apply to the overall modulated bitstream, not just to the components of it that represent discrete sequences of plain data bits. (This rule must hold for any arbitrary pair of codes, without exception, because the input data may be any arbitrary sequence of bits.) The IBM GCR code above meets this condition, since the maximal run length of zeros at the beginning of any 5-bit code is one, and likewise the maximal run length at the end of any code is one, making a total run length of two at the junction between adjacent codes. (An example of the maximal run length occurring between codes can be seen in the example given above, where the code for the data '0010' ends with a zero and the code for the next data, '1101', begins with a zero, forming a run of two zeros at the junction of these two 5-bit codes.)

MFM: (1,3) RLL[edit]

Modified frequency modulation begins to get interesting, because its special properties allow its bits to be written to a magnetic medium with twice the density of an arbitrary bit stream. There is a limit to how close in time flux transitions can be for reading equipment to detect them, and that constrains how closely bits can be recorded on the medium: In the worst case, with an arbitrary bit stream, there are two consecutive ones, which produces two consecutive flux transitions in time, so bits must be spaced far enough apart that there would be sufficient time between those flux transitions for the reader to detect them. But this code imposes a constraint of d = 1, i.e. there is a minimum of one zero between each two ones. This means that in the worst case, flux transitions are two bit times apart, so the bits can be twice as close together as with the arbitrary bit stream without exceeding the reader's capabilities.

This doubled recording density compensates for the 1/2 coding rate of this code (it takes two bits to represent one bit of real information) and makes it equivalent to a rate-1 code.

DataEncoded
0x0
101

Here 'x' is the complement of the previous encoded bit (which is also the previous data bit). Except for the clock bits – that 'x' bit, and the '0' in the '01' code – this is the same as the FM table, and that is how this code gets its name. The inserted clock bits are 0 except between two 0 data bits.

Example:

(1,7) RLL[edit]

(1,7) RLL maps 2 bits of data onto 3 bits on the disk, and the encoding is done in 2- or 4-bit groups. The encoding rules are: (x, y) becomes (NOT x, x AND y, NOT y), except (x, 0, 0, y) becomes (NOT x, x AND y, NOT y, 0, 0, 0).[6]When encoding according to the table below, the longest (last in the table) match must be used; those are exceptions handling situations where applying the earlier rules would lead to a violation of the code constraints.

DataEncoded
00101
01100
10001
11010
00 00101 000
00 01100 000
10 00001 000
10 01010 000

Example:

(2,7) RLL[edit]

(2,7) RLL is rate-​12 code, mapping n bits of data onto 2n bits on the disk, like MFM, but because the minimal run length is 50% longer (3 bit times instead of 2), the bits can be written faster, achieving 50% higher effective data density. The encoding is done in 2-, 3- or 4-bit groups.

Western Digital WD5010A, WD5011A, WD50C12

Data(2,7) RLL encoded
111000
100100
000100100
010000100
011001000
001100001000
001000100100

Seagate ST11R, IBM

Data(2,7) RLL encoded
111000
100100
000000100
010100100
011001000
001100001000
001000100100

Perstor Systems ADRC

Data(2,7) RLL encoded
111000
100100
000100100
010000100
001001000
011100001000
011000100100

The encoded forms begin with at most 4, and end with at most 3 zero bits, giving the maximal run length of 7.

Example:

DC-free (1,7) RLL[edit]

There is also an alternate (1,7) RLL encoding that is sometimes used to avoid a DC bias (which helps when sending a signal over a long distance or with some types of recording media).

DataEncoded
00x01
01010
10x00
11 00010 001
11 01x00 000
11 10x00 001
11 11010 000

Here 'x' is the complement of the previous encoded bit (i.e. 1 if the previous bit was 0, and 0 if the previous bit was 1).

Example:

HHH(1,13)[edit]

The HHH(1,13) code is a rate-2/3 code developed by three IBM researchers (Hirt, Hassner, and Heise) for use in the 16 MB/s IrDA VFIR physical layer.[7] Unlike magnetic encoding, this is designed for an infrared transmitter, where a 0 bit represents 'off' and a 1 bit represents 'on'. Because 1 bits consume more power to transmit, this is designed to limit the density of 1 bits to less than 50%. In particular, it is a (1,13|5) RLL code, where the final 5 indicates the additional constraint that there are at most 5 consecutive '10' bit pairs.

DataEncoded
00010
01001
10100
11101
01 10001 000
01 11010 000
11 10101 000
11 11100 000
00 11 00010 000 000
00 11 01001 000 000
10 11 00100 000 000
10 11 01101 000 000
00 11 10 11010 000 000 000
10 11 10 11100 000 000 000

The first eight rows describe a standard (1,7)-RLL code. The additional six exceptions increase the maximal run of zeros to 13 (in the legal pattern 100 000 000 000 001, which represents 10 11 10 11, followed by 01), but limit the maximal average ones density to ​13. The longest run of 1–0 pairs is 000 101 010 101 000.

Disk

This code limits the ones density to between ​112 and ​13, with an average of 25.8%.

Examples[edit]

For example, let us encode the bit sequence 10110010 with different encodings

EncodingDataEncoded
RLL(0,1)101100101110111110101110
RLL(0,2)1011 001001011 10010
RLL(1,3)101100100100010100100100
RLL(1,7)10 11 00 10001 010 101 001
RLL(2,7)10 11 00100100 1000 00100100

Densities[edit]

Suppose a magnetic tape can contain up to 3200 flux reversals per inch. A modified frequency modulation, or (1,3) RLL encoding, stores each data bit as two bits on tape, but since there is guaranteed to be one 0 (no flux reversal) bit between any 1 (flux reversal) bits, then it is possible to store 6400 encoded bits per inch on the tape, or 3200 data bits per inch. A (1,7) RLL encoding can also store 6400 encoded bits per inch on the tape, but since it only takes 3 encoded bits to store 2 data bits, this is 4267 data bits per inch. A (2,7) RLL encoding takes 2 encoded bits to store each data bit, but since there is guaranteed to be two 0 bits between any 1 bits, then it is possible to store 9600 encoded bits per inch on the tape, or 4800 data bits per inch.

The flux-reversal densities on hard drives are significantly greater, but the same improvements in storage density are seen by using different encoding systems.

See also[edit]

  • Eight-to-fourteen modulation and EFMplus are DC-free (2,10) RLL codes used on CDs and DVDs, respectively.
  • Self-synchronizing code and bit synchronization

References[edit]

This article is based on material taken from the Free On-line Dictionary of Computing prior to 1 November 2008 and incorporated under the 'relicensing' terms of the GFDL, version 1.3 or later.

  1. ^A Quarter Century of Disk File Innovation, IBM Journal of Research and Development.
  2. ^P. A. Franaszek (1972), “Run-Length-Limited Variable Length Coding with Error Propagation Limitation”, U.S. Patent 3,689,899.
  3. ^Five decades of disk drive industry firsts, DISK/TREND, Inc., publisher of market studies of the worldwide disk drive and data storage industries. web.archive.org.
  4. ^Kees Schouhamer Immink (December 1990). 'Runlength-Limited Sequences'. Proceedings of the IEEE. 78 (11): 1745–1759. doi:10.1109/5.63306. A detailed description is furnished of the limiting properties of runlength limited sequences.
  5. ^Kees A. Schouhamer Immink (November 2004). Codes for Mass Data Storage Systems (Second fully revised ed.). Eindhoven, The Netherlands: Shannon Foundation Publishers. ISBN90-74249-27-2. Retrieved 2015-08-23.
  6. ^Mee, C. Denis; Daniel, Eric D. (1996). Magnetic Storage Handbook (2nd ed.). McGraw Hill. ISBN0-07-041275-8.
  7. ^Hirt, Walter; Hassner, Martin; Heise, Nyles (February 2001), 'IrDA-VFIr (16 Mb/s): modulation code and system design', IEEE Personal Communications, 8 (1): 58–71, doi:10.1109/98.904900.

External links[edit]

Retrieved from 'https://en.wikipedia.org/w/index.php?title=Run-length_limited&oldid=999195680'